Skip to content

T-5A3-A-5 - CHP hydrogen production

Definition

This emission source is defined by the IPCC in TBD.

Transition Elements

This activity has the following mitigation options modelled as transition elements:

Activity Model

This emission source is modelled with Combustion as:

WORK:
combustion
(kwh)
OPERATIONS:
(kwh)
1 / ( energy_efficiency_chp_hydrogen_to_district_heat + energy_efficiency_chp_hydrogen_to_electricity )
(kwh/kwh)
stock_chp_hydrogen
energy_efficiency_chp_hydrogen_to_district_heat
(kwh/kwh)
energy_efficiency_chp_hydrogen_to_electricity
(kwh/kwh)
RESOURCE:
district_heat
(kwh)
RESOURCE:
electricity
(kwh)
EMISSIONS
STOCK
RESOURCE:
hydrogen
(kwh)
1
(kwh/kwh)
emission_factor_climate_neutral_hydrogen_kwh_to_co2e (g_co2e/kwh)

Parameters

Parameter Unit Description
emission_factor_climate_neutral_hydrogen_kwh_to_co2e g_co2e_kwh Emission factor hydrogen (climate neutral)
energy_efficiency_chp_hydrogen_to_district_heat percent Energy efficiency of CHP hydrogen to electricity
energy_efficiency_chp_hydrogen_to_electricity percent Energy efficiency of CHP hydrogen to district heat
stock_chp_hydrogen kwh Combined heat and power (CHP) - hydrogen

YAML Specification

version: 2.1.0
operation:
  growthType: false
  variable: stock_chp_hydrogen
work:
- name: combustion
  unitOfMeasure: kwh
  operationToWork:
    unitOfMeasure: kwh/kwh
    expression: 1 / ( %[0] + %[1] )
    variables:
    - energy_efficiency_chp_hydrogen_to_district_heat
    - energy_efficiency_chp_hydrogen_to_electricity
  input:
  - resource: hydrogen
    unitOfMeasure: kwh
    resourceToWork:
      unitOfMeasure: kwh/kwh
      expression: '1'
    emissionFactor:
      unitOfMeasure: g_co2e/kwh
      expression: '%[0]'
      variables:
      - emission_factor_climate_neutral_hydrogen_kwh_to_co2e
  output:
  - resource: district_heat
    primary: true
    unitOfMeasure: kwh
    workToResource:
      unitOfMeasure: kwh/kwh
      expression: '%[0]'
      variables:
      - energy_efficiency_chp_hydrogen_to_district_heat
  - resource: electricity
    unitOfMeasure: kwh
    workToResource:
      unitOfMeasure: kwh/kwh
      expression: '%[0]'
      variables:
      - energy_efficiency_chp_hydrogen_to_electricity
50% This page is roughly halfway complete and is actively being developed.